DATAMATH CALCULATOR MUSEUM |
Features
These new types of displays
incorporating „keep alive“ cathodes. Advantages of these devices
include:
| |||||||||||||||||||
Usage |
Heathkit IC-2008A
Technical Specification |
| Item | Min | Typ | Max | Unit | Comments |
| Anode Supply Voltage | 160 | 180 | 200 | V | DC-Characteristics |
| Anode-to-Anode Differential Voltage | 14 | V | " | ||
| Anode-to Cathode Voltage Drop | 135 | V | " | ||
| Cathode Current - per segment | 130 | 330 | 420 | uA | " |
| Cathode Current - decimal point | 65 | 135 | 190 | uA | " |
| Cathode Current – keep alive | 10 | 50 | uA | " | |
| Power Dissipation - All segments lighted | 325 | mW | " | ||
| Anode Voltage Swing | 30 | 45 | 90 | V | Multiplex Characteristics |
| Anode On Time | 80 | 200 | uS | " | |
| Interdigit Blanking Time (*) | 40 | 55 | uS | " | |
| Refresh Periode – w/o keep alive | 3 | mS | " | ||
| Refresh Periode – with keep alive | 10 | mS | " | ||
| Cathode Voltage Swing | 30 | 50 | 120 | V | " |
| Cathode Bias Voltage | 30 | 50 | 120 | V | " |
| Operating Temperature | 0 | 70 | °C | ||
| Storage Temperature | -55 | 125 | °C |
(*) No anode or cathode blanking is required for proper display performance. Some blanking, however, may be advantageous in eliminating time overlap of signals due to circuit characteristics.
HousingThe SP-353 uses a special
30 pin glass-package. | |
Pin Description |
| Pin | Function | Pin | Function | Pin | Function |
| C1 | Segment A | B1 | Segment A | A1 | Segment A |
| C2 | Segment B | B2 | Segment B | A2 | Segment B |
| C3 | Segment C | B3 | Segment C | A3 | Segment C |
| C4 | Segment D | B4 | Segment D | A4 | Segment D |
| C5 | Segment E | B5 | Segment E | A5 | Segment E |
| C6 | Segment F | B6 | Segment F | A6 | Segment F |
| C7 | Segment G | B7 | Segment G | A7 | Segment G |
| C8 | Segment DP | B8 | Segment DP | A8 | Segment DP |
| C9 | Anode | B9 | Anode | A9 | Anode |
| C10 | keep alive | B10 | keep alive | A10 | keep alive |
![]()
Burroughs™, Sperry™ and Panaplex™ are trademarks of Unisys Corporation.
If you have additions to the above datasheet please email: joerg@datamath.org.
© Joerg Woerner, March 16, 2001. No reprints